Sitemap Contact
 
Home >Products >  Relay series  > Latching Relay  
 
Product list
Product manualsff
2010/4/21
The use of solid state relays guidelines
2010/4/21
Car relay use guidelines
2010/4/21
Failure causes SuZha table. Relays
2010/4/21
Relay use attention
2010/4/21
The relay selection principle
 
Products are introduced in detail
ALR04/60
-This type of other products
1.Applcation to the meters of 5(20)A,5(30)A,10(40)A and the compound swtiches of 10KVA,16KVA,20KVA;
2.Contacts can be controled by the handle switches;
3.Dimensions:100x50x21(mm);
No
No
No
No
 
Red Rectangle Download (PDF Datasheet)
Red Rectangle Inquiry of ALR04/60

 TYPE

 GRT508D-60A

 Contact Form

 3B

 Contact Resistance

 Max.1.5m

 Contact Material

 Silver Alloy

 Contact Rating

 60A 250VAC

 Max.Switching Voltage

 250VAC

 Max.Switching Current

 60A

 Max.Switching Power

 15,000VA

 Life

 Mechanical

 5105OPS

 Electrical

 1104OPS

 Coil Rated Voltage

 924VDC

 Operate Volage

 70%

 Coil Power

 3.5W/7.0W(Single/Double)

 Dielectric Strength

 Coil&Contact

 4000VAC 50/60Hz(1Minute)

 between open  contacts

 2000VAC 50/60Hz(1Minute)

 between contact  poles  4000VAC 50/60Hz(1Minute)

 Insulation Resistance

 1000M¦¸Min.(500VDC)

 Ambient Temperature

 -40+70

 Operate Time

 50ms Max

 Relative humidity  45%-90% RH
 Vibration  10-55Hz,1.5mm
 Impulsion  98m/s2

 Weight

 150g